Two different units get called the same thing in Singapore, and the confusion costs people money. A ceiling cassette sits flush in your ceiling and blows air out through a square grille. A ducted unit hides completely above the ceiling and pushes air through hidden ducts to vents in different parts of the room. They are not the same product, they do not cost the same, and they do not suit the same spaces.
This guide explains both properly: how each one works, what ceiling depth you actually need, what they cost installed in Singapore, and the servicing difference nobody mentions until the first water stain appears. We install and service both.

Quick answer
Choose a ceiling cassette if you want strong, even cooling in one open space and you have (or can build) a false ceiling with about 300mm of clearance. It is the simpler and cheaper of the two. In fact, it is what most Singapore shops, cafes and clinics end up with.
Choose ducted if you want the aircon to be invisible, or you need to cool several zones from one unit. It needs more ceiling depth, more planning and more money. So it only makes sense if the ceiling design is being done anyway.
Choose neither if you have a standard HDB flat with no false ceiling. A wall-mounted split system will cool the same room for a fraction of the cost, and we will tell you that rather than sell you a ceiling job.
What a ceiling cassette actually is
The indoor unit sits inside the ceiling void. Only the decorative panel shows, flush with the ceiling, with the grille in the middle and air coming out of the edges.
To give you a real sense of the size, the Mitsubishi Mr Slim cassette we install (PLY-ZM50EA, 18,000 BTU) has an 840 × 840mm ceiling panel and a body 258mm deep, weighing 21kg. That 258mm is the number that decides whether your ceiling can take one, and it is why people with a 150mm plasterboard drop are disappointed.
One-way, two-way and four-way: what the numbers mean
Cassettes are described by how many sides they blow air from.
- Four-way cassette — air out of all four edges. The standard choice for a square or open room, because the coverage is even in every direction. This is what most Singapore shops and offices get.
- Two-way cassette — air from two opposite sides. Suits a long, narrow space: a corridor-shaped retail unit, a narrow clinic room.
- One-way cassette — air from a single side. Usually used where the unit has to sit near a wall, or in a small room where a four-way would blow straight at people.
- Mini cassette — a smaller four-way, usually around 600 × 600mm so it drops into a standard ceiling tile grid. Lower capacity, popular in small offices and treatment rooms.
If a supplier quotes you “a cassette” without saying which, ask. The wrong airflow direction in a narrow room means one end is cold and the other is not, and no amount of servicing fixes a layout decision.
What ducted means, and why it costs more
With a ducted system the entire indoor unit is hidden above the ceiling. Air is pushed through insulated ducts to grilles placed where you want them. You see nothing but the vents.
That invisibility is the whole point, and it is also the cost. You are paying for the unit, plus ductwork, plus grilles, plus a deeper ceiling, plus the design work to get the air volumes right at each outlet. Get the duct sizing wrong and the far room never cools properly, and that is a design problem no amount of servicing afterwards will fix.
Ducted earns its money in two situations: when the interior design will not tolerate a visible unit, and when one system has to serve several rooms that are used at the same time.
Side by side
| Ceiling cassette | Ducted | |
|---|---|---|
| What you see | Square panel flush in the ceiling | Only the vents |
| Ceiling depth needed | Around 300mm (unit body 258mm plus clearance) | More, and a path for the ducts |
| Rooms served | One open space per unit | Several zones from one unit |
| Installed cost | Lower | Higher, ductwork and design on top |
| Servicing access | Panel drops down, straightforward | Access hatch needed, ducts need checking too |
| Best for | Shops, cafes, clinics, offices, open living areas | Landed homes, high-spec interiors, multi-zone layouts |
What it costs in Singapore
We list two commercial ranges openly with installed prices, so you can compare like for like before anyone visits:
- Mitsubishi Electric Mr Slim ceiling cassettes, 18k to 43k BTU. The 18k (SUY-ZM50VA with PLY-ZM50EA) is 5 ticks; the larger sizes are 4 ticks.
- Mitsubishi Electric Mr Slim ducted units, 18k to 43k BTU.
- Daikin SkyAir ceiling cassettes, 18k to 38k BTU, all 4 ticks.
- Daikin SkyAir ducted units, 18k to 38k BTU.
Each range page shows every size side by side with its rated capacity and installed price, and links to the full specification.
What that published price includes: both units, and standard installation using commercial-grade materials — gauge-22 copper piping, K-Flex Titan insulation, 16mm drainage, proper interconnect and power cabling — plus a one-year Lion City workmanship warranty on top of the manufacturer’s.
What is quoted separately, because it depends entirely on your site:
- Ceiling works — cutting the opening, patching back, painting. The cost depends on your ceiling type and how many units go in, so we price it after the site survey.
- Electrical work — a new 20A or 32A isolator and cabling from your DB box, done by licensed partner electricians.
- Stainless steel compressor bracket where the outdoor unit needs mounting, $163.50 per set.
- Longer-than-standard pipe runs, which on commercial sites is common.
- Ductwork on a ducted system, always site-specific.
All prices include 9% GST. We do a free site survey before quoting, because anyone giving you a firm ceiling-works number over the phone is guessing.
If you run an SME, the 5-tick Mitsubishi units appear on the pre-approved list for the Energy Efficiency Grant, which can co-fund up to 70% of an energy-efficient system.
The servicing difference nobody mentions
This is the part that surprises people after installation.
A wall-mounted unit drains by gravity. A ceiling cassette usually cannot, because it sits above the level it needs to drain to, so it has a condensate pump pushing water up and out. That pump is a moving part, it sits in the dirtiest water in your system, and when it fails the water has nowhere to go but through your ceiling.
The first symptom is almost always a brown ring on the plasterboard, by which point you are paying for ceiling repair as well as aircon repair. Cassettes and ducted units need their drain pans and pumps checked as part of routine aircon servicing, not just their filters.
The other difference is access. Servicing a cassette means dropping the panel from a ladder, and on a commercial site that may mean working around trading hours. Ducted adds the ducts themselves, which collect dust and need checking. Tell us the unit type and where it is when you ask about servicing, and we will quote for your site.
For shops and offices running these units 10 to 12 hours a day, a commercial servicing contract usually works out better than ad-hoc visits.
Before you commit, check these
- Measure the ceiling void properly. Not the drop from the slab to the plasterboard as drawn, the actual clear space with the beams, sprinklers, lighting and existing services in it. 258mm of unit needs more than 258mm of void.
- Find out where the condensate goes. If there is no sensible drainage route, you are committing to a pump and to the maintenance it brings.
- Check your power supply. Commercial cassettes often need a dedicated isolator the premises does not yet have.
- Decide before the ceiling is built. Retrofitting a cassette into a finished ceiling costs considerably more than planning it in, and ducted retrofits are worse.
- Ask who maintains it afterwards. Not every aircon company services cassette and ducted units. Confirm before you buy, not when it leaks.
Frequently asked questions
Can I install a ceiling cassette in an HDB flat?
Only if you build a false ceiling deep enough to take it, which most HDB flats do not have. Standard HDB ceiling heights leave very little room once you drop a ceiling, and the cost of the ceiling work usually outweighs any benefit over a wall-mounted unit. We would rather tell you that upfront.
What is the difference between a cassette and a ducted unit, in one sentence?
A cassette is visible as a flush square panel and cools one open space; a ducted unit is completely hidden and pushes air through ducts to vents in several places.
How much ceiling space does a cassette need?
Plan for roughly 300mm of clear void. The 18k BTU Mitsubishi cassette body is 258mm deep with an 840 × 840mm panel, and you need working clearance above it as well.
Is a cassette aircon more expensive to service?
It is a different job from a wall unit: ladder access, a drain pan and condensate pump to check, and on a commercial site the work often has to fit around opening hours. Tell us the unit type and location and we will quote for your site.
Do cassette units leak?
They can, and when they do it shows on your ceiling. Nearly always it is the condensate pump or a blocked drain pan rather than the unit itself, and nearly always it was preventable with routine servicing.
What size cassette do I need for my shop?
It depends on floor area, ceiling height, glass frontage, how many people are in the space and what equipment is running — an F&B kitchen changes the maths completely. That is what the site survey is for. Guessing capacity from floor area alone is how shops end up with a unit that runs flat out and never quite cools.
Do you service cassette and ducted units installed by someone else?
Yes. Brand and installer make no difference to us.
Want a straight answer on which one fits your space?
Send us a photo of the ceiling and tell us roughly the size of the room. We will tell you whether a cassette fits, whether ducted is worth the extra, or whether a normal wall unit does the job for a lot less money. Free site survey, exact quote before anything is scheduled.
WhatsApp +65 8818 5781 · Call +65 8818 5781 · Book online
5.0★ across 2,300+ Google reviews · BizSafe Level 3 certified · 25,000+ jobs since 2016 · Serving all of Singapore.